MPAK Logo
phone
iMPAKting
 

     Disk Storage Products List

     SAS RAID Product List

     SAS Products:

Fibre to SAS/SATA

SAS to SAS/SATA

iSCSI to SAS/SATA

Momentum-View-A

Eonpath

SanWatch

 
 
       R1284 / R1274                               |    Specifications    |     Accessories    |    Datasheet     
           
   
  • Expansion enclosure for SAS to SAS RAID systems
    • SAS drives for high performance and high reliability
    • SATA drives for low cost and high capacity applications
  • Highest density, 12 drives in 2U rack space
  • Redundant or single JBOD controllers
  • Two (2) SAS 4x wide ports per controller
  • Diagnostics LED panel
  • Proprietary enclosure service via connections (in-band) with the managing RAID enclosure
  • Path redundancy via separate SAS domains (S12S-J1002-R)
   
 
           
Host-to-Drive Interface
JBOD Model
Corresponding
RAID Subsystem(s)
Configuration Form Factor
Model Max. Connection
SAS to SAS/SATA II
S1274
4 JBODs
Single Expander Controller
2U Rackmount
SAS to SAS/SATA II

S1284

3 JBODs
Redundant Expander Controllers
2U Rackmount
 
  Specifications        
  System Components        
 
  • Redundant or single JBOD controller configurations
  • Fault-tolerant modules interfaced through a common backplane
  • Redundant, hot swappable 460W/530W power supply units
  • Redundant, dual-speed cooling modules
  • LED diagnostics panel
 
  Host Interface        
 
  • Two (2) SAS 4x wide ports per controller.
  • Proprietary enclosure service via in-band methodology
 
  Drive Interface        
 
  • Twelve (12) hot swappable SAS/SATA II disk drives
 
 

Management

       
 
  • Management of multiple enclosures via RAID firmware and/or through GUI
  • Module status LED indicators:
  • Six (6) on LED panel (1 service LED and 5 status LEDs)
  • Two (2) per drive tray
  • Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
  • One (1) per power supply unit
  • Two (2) per cooling module
 
  Physical/Electrical  
  Interfaces  
 
  • Host Interface: Eight (8) SMP PHYs interfaced through two (2) SAS 4x wide ports per controller.
  • Drive Interface: 3Gbps SAS/ SATA II
 
  Power Supply Module  
  Redundant hot-swappable power supplies with PFC  
 
Input
  100VAC @ 8A/10A or 240VAC @ 4A/5A
   with PFC (auto-switching)
  50 to 60Hz/ 47 to 63Hz
Output
  460W/ 530W (J1000-G/J1002-R)
  +12.0V
  32A max.
  + 5.0V
  32A max.
  + 3.3V   30A max.
 
  Cooling Module  
 

Two (2) redundant, dual-fan cooling modules

 
 
Speed
High or low rotation speed controlled by firmware
Maximum Air Flow
R1274: 1.3 m3/min (high speed); 0.9 m3/min (low speed)
R1284: 90CFM(high speed); 70.7CFM (low speed)
 
  Environmental Specifications  
 
Temperature Operating: 5° to 40° C (35° C if battery is applied)
Non-operating: - 40° to 60°C (-40° F to 140° F)
Relative Humidity
5% to 95% (non condensing - operating and non-operating)
Altitude
Operating: sea level to 10,000 ft
 
  Dimensions  
 
  • With Handles: 88mm(H) x 482(W) x 516/522(D) mm
 
  System weight  
 
  • Net weight: R1274 17.6 kg ( 38.80 pounds); R1284 15.7kg ( 34.61 pounds )
  • Gross weight: R1274 25.5 kg ( 56.22 pounds); R1284 23.6kg ( 52.03 pounds )
 
   
  Return to Top  
 

Home | Products | Solutions | Support | Company | News | Partners | Privacy | Contact Us