SANnet II Blade Specifications

Effectively managing your storage requires the consideration of many factors, including cost per GB, performance, high availability, ease of management, and even the amount of space required to house the equipment. Your users expect reliability and speed in accessing their applications and data, and your company expects you to make the most out of its space and investment. The SANnet II Blade delivers on all of these aspects, and more.

General
• Storage architecture: DAS
• Supported platforms: Microsoft Windows, Red Hat Linux, Novell NetWare, Sun Solaris, IBM AIX and HP-UX
• Supported drives: 36GB, 73GB or 146GB at 10,000 RPM and 36GB or 73GB at 15,000 RPM
• Total capacity: Up to 1.75TB
• Total disks: Up to 12
• Mounting options: Rack mount

Models
• RAID base systems: Single controller with up to 4 drives
• RAID expansion systems: Up to 4 drives
• JBOD systems: Up to 4 drives

Hosts
• Interface type: Ultra160 SCSI
• Internal paths: 1, 2 or 3

Drives
• Interface type: Ultra160 SCSI, single-port
• External ports: 1, 2 or 3
• Internal paths: 1, 2 or 3

RAID
• Levels supported: RAID 0, 1, 3, 5, 10, 30, 50 or JBOD
• Cache memory: 512MB per controller
• Cache backup: Battery, 72 hours
• Arrays per system: 1 to 8
• Partitions per array: 1 to 8
• Volumes per system: 1 to 64

Management
• Interface types: Serial, Ethernet, SCSI
• Protocols supported: VT100, TCP/IP, SNMP, API, SAF-TE
• Management consoles: Terminal, GUI, CLI

Dependability
• Reliability: Telco and military certified for ruggedness, load-sharing and load-balancing power supplies, temperature controlled cooling fans, hardware RAID protection for data (optional)
• Availability: Redundant host data paths, drive data paths, disks (with optional hardware RAID or host based RAID), power inputs, power supplies and cooling fans
• Serviceability: Hot swap removable disks, power supplies and cooling fans, hot serviceable controller, IO module and SCSI termination module
• Uptime: 99.9998%

Electrical - AC Input
• Voltage: 100-240VAC at 50/60 Hz, single-phase
• Current: 4A maximum per input
• Power: 100W typical

Electrical - DC Input
• Voltage: -48VDC or -60VDC
• Current: 8A maximum per input
• Power: 100W typical

Environmental - Operating
• Temperature: 5°C to 40°C (41°F to 104°F)
• Humidity: 10% to 90% 27°C maximum wet bulb, non-condensing
• Altitude: -30 to 3048 m (-100 to 10,000 ft.)
• Shock: 5.0 G, 11-ms, half-sine
• Vibration: 0.2 G, 5-500 Hz, swept-sine
• Heat: 350 BTU/hour

Environmental - Non-Operating
• Temperature: -40°C to 65°C (-40°F to 149°F)
• Humidity: 0% to 90% 38°C maximum wet bulb, non-condensing
• Altitude: -30 to 12,192 m (-100 to 40,000 ft.)
• Shock: 15.0 G, 11-ms, half-sine
• Vibration: 1.0 G, 5-500 Hz, swept-sine

Regulatory
• Safety: UL listed, cUL, CE, CSA-C22.2 No.60950-00, EN 60950:2000, IEC 60950, GS, GOST, S-Mark
• Emissions: FCC Part 15 Class B, ICES-003, EN 300 386, EN 55022 Class B, VCCI Class B, AS/NZS 3548 Class B, BMSI Class B
• Harmonics and flicker: EN 61000-3-2,EN 61000-3-3
• Immunity: EN 300 386, EN 55024
• Other: NEBS Level 3 (GR-63-CORE, GR-1089-CORE), MIL-STD 810F, ETSI EN 300 019

Physical
• Height: 1.75 inches (1U)
• Width: 17.6 inches
• Depth: 21.0 inches
• Weight: 30 pounds

 

 

Get Adobe Reader


Disk Storage
High performance, cost effective solutions to help ensure your data is protected and available on-demand.
Backup
Reliable backup solutions that offer disaster recovery and storage management to help maintain a continuous operation.
Network Storage & IP Appliances
High performing network attached storage products. Unique IP appliances and D2D & D2D2T backup.
Computing
Computing platforms, LINUX clusters and cost effective storage servers that provide high performance and optimal availability.
Application Specific Architecture
Products developed specifically for vertical markets.