Effectively
managing your storage requires the consideration
of many factors, including cost per GB,
performance, high availability, ease of
management, and even the amount of space
required to house the equipment. Your
users expect reliability and speed in
accessing their applications and data,
and your company expects you to make the
most out of its space and investment.
The SANnet II Blade delivers on all of
these aspects, and more.
General
• Storage architecture: DAS
• Supported platforms: Microsoft
Windows, Red Hat Linux, Novell NetWare,
Sun Solaris, IBM AIX and HP-UX
• Supported drives: 36GB, 73GB or
146GB at 10,000 RPM and 36GB or 73GB at
15,000 RPM
• Total capacity: Up to 1.75TB
• Total disks: Up to 12
• Mounting options: Rack mount
Models
• RAID base systems: Single controller
with up to 4 drives
• RAID expansion systems: Up to
4 drives
• JBOD systems: Up to 4 drives
Hosts
• Interface type: Ultra160 SCSI
• Internal paths: 1, 2 or 3
Drives
• Interface type: Ultra160 SCSI,
single-port
• External ports: 1, 2 or 3
• Internal paths: 1, 2 or 3
RAID
• Levels supported: RAID 0, 1, 3,
5, 10, 30, 50 or JBOD
• Cache memory: 512MB per controller
• Cache backup: Battery, 72 hours
• Arrays per system: 1 to 8
• Partitions per array: 1 to 8
• Volumes per system: 1 to 64
Management
• Interface types: Serial, Ethernet,
SCSI
• Protocols supported: VT100, TCP/IP,
SNMP, API, SAF-TE
• Management consoles: Terminal,
GUI, CLI
Dependability
• Reliability: Telco and military
certified for ruggedness, load-sharing
and load-balancing power supplies, temperature
controlled cooling fans, hardware RAID
protection for data (optional)
• Availability: Redundant host data
paths, drive data paths, disks (with optional
hardware RAID or host based RAID), power
inputs, power supplies and cooling fans
• Serviceability: Hot swap removable
disks, power supplies and cooling fans,
hot serviceable controller, IO module
and SCSI termination module
• Uptime: 99.9998%
Electrical - AC Input
• Voltage: 100-240VAC at 50/60 Hz,
single-phase
• Current: 4A maximum per input
• Power: 100W typical
Electrical - DC Input
• Voltage: -48VDC or -60VDC
• Current: 8A maximum per input
• Power: 100W typical
Environmental - Operating
• Temperature: 5°C to 40°C
(41°F to 104°F)
• Humidity: 10% to 90% 27°C
maximum wet bulb, non-condensing
• Altitude: -30 to 3048 m (-100
to 10,000 ft.)
• Shock: 5.0 G, 11-ms, half-sine
• Vibration: 0.2 G, 5-500 Hz, swept-sine
• Heat: 350 BTU/hour
Environmental - Non-Operating
• Temperature: -40°C to 65°C
(-40°F to 149°F)
• Humidity: 0% to 90% 38°C maximum
wet bulb, non-condensing
• Altitude: -30 to 12,192 m (-100
to 40,000 ft.)
• Shock: 15.0 G, 11-ms, half-sine
• Vibration: 1.0 G, 5-500 Hz, swept-sine
Regulatory
• Safety: UL listed, cUL, CE, CSA-C22.2
No.60950-00, EN 60950:2000, IEC 60950,
GS, GOST, S-Mark
• Emissions: FCC Part 15 Class B,
ICES-003, EN 300 386, EN 55022 Class B,
VCCI Class B, AS/NZS 3548 Class B, BMSI
Class B
• Harmonics and flicker: EN 61000-3-2,EN
61000-3-3
• Immunity: EN 300 386, EN 55024
• Other: NEBS Level 3 (GR-63-CORE,
GR-1089-CORE), MIL-STD 810F, ETSI EN 300
019
Physical
• Height: 1.75 inches (1U)
• Width: 17.6 inches
• Depth: 21.0 inches
• Weight: 30 pounds
|
|