SANnet® II SATA Special Edition is
an affordable Switchless SAN™ solution
for Windows and Linux servers. Ideal as
an entry-level SAN and for storage migration
or consolidation, SANnet II SATA Special
Edition provides up to 3TB of reliable
storage. It supplies up to 12 servers
with a fully integrated Fibre Channel
SAN storage solution for less than the
cost
of direct attached storage.
General
• Storage architecture: SAN or DAS
• Supported platforms: Microsoft
Windows, Red Hat Linux
• Supported drives: 250GB at 7,200
RPM
• Total capacity: Up to 3TB
• Total disks: Up to 12
• Mounting options: Rack mount
Models
• RAID base systems: Redundant or
single controllers with up to 12 drives
Hosts
• Interface type: 2 Gbit Fibre Channel
• External ports: 6 or 12
• Internal paths: 2 or 4
Drives
• Interface type: 1.5 Gbit Serial
ATA, dual-ported
RAID
• Levels supported: RAID 0, 1, 3,
5, 10, 30, 50 or JBOD
• Cache memory: 256MB per controller
• Cache backup: Battery, 72 hours
• Arrays per system: 1 to 8
• Partitions per array: 1 to 128
• Volumes per system: 1 to 1024
Management
• Interface types: Serial, Ethernet,
FC
• Protocols supported: VT100, TCP/IP,
SNMP, API, SES
• Management consoles: Terminal,
GUI, CLI
Dependability
• Reliability: Load-sharing and
load-balancing power supplies, temperature
controlled cooling fans, hardware RAID
protection for data
• Availability: Redundant controllers
(optional), host data paths, drive data
paths, disks, power inputs, power supplies,
cooling fans and
enclosure management, non-disruptive firmware
updates with redundant controllers
• Serviceability: Hot swap removable
controllers (when redundant), IO modules,
disks, power supplies, cooling fans and
cache batteries
• Uptime: 99.9998%
Electrical - AC Input
• Voltage: 100-240VAC at 50/60 Hz,
single-phase
• Current: 5.0A maximum per input
• Power: 300W typical
Electrical - DC Input
• Voltage: -48VDC or -60VDC
• Current: 18A maximum per input
• Power: 300W typical
Environmental - Operating
• Temperature: 5°C to 40°C
(41°F to 104°F)
• Humidity: 10% to 90% 27°C
maximum wet bulb, non-condensing
• Altitude: -30 to 3048 m (-100
to 10,000 ft.)
• Shock: 5.0 G, 11-ms, half-sine
• Vibration: 0.2 G, 5-500 Hz, swept-sine
• Noise: Less than LwAd 6.6 B (66
dB)
• Heat: 900 BTU/hour
Environmental - Non-Operating
• Temperature: -40°C to 65°C
(-40 °F to 149°F)
• Humidity: 0% to 90% 38°C maximum
wet bulb, non-condensing
• Altitude: -30 to 12,192 m (-100
to 40,000 ft.)
• Shock: 15.0 G, 11-ms, half-sine
• Vibration: 1.0 G, 5-500 Hz, swept-sine
Regulatory
• Safety: UL listed, cUL, CE, CSA-C22.2
No.60950-00, EN 60950:2000, IEC 60950,
GS, GOST, S-Mark
• Emissions: FCC Part 15 Class B,
ICES-003, EN 300 386, EN 55022 Class B,
VCCI Class B, AS/NZS 3548 Class B, BMSI
Class B
• Harmonics and flicker: EN 61000-3-2,EN
61000-3-3
• Immunity: EN 300 386, EN 55024
Physical
• Height: 3.5 inches (2U)
• Width: 17.6 inches
• Depth: 21.0 inches
• Weight: 60 pounds
|
|